The suppression device is normally wired in series with the load device.

A) True
B) False

Correct Answer

verifed

verified

An addressing conflict is caused by the same address being used for two or more coil instructions in the same program.

A) True
B) False

Correct Answer

verifed

verified

Which of the following is not normally included in the array of status indicators found on the processor module?


A) Memory OK
B) Wiring OK
C) Battery OK
D) Power supply OK

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

Preparing a PLC control process for start-up is called:


A) commissioning
B) troubleshooting
C) validating
D) installing

E) B) and D)
F) A) and B)

Correct Answer

verifed

verified

Editing a PLC program normally refers to:


A) replacement of an existing program.
B) monitoring of an existing program.
C) making changes to an existing program.
D) all of these.

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

In which of the following program modes are modifications executed immediately on entry of the instruction?


A) Continuous test mode
B) Single scan test mode
C) Off-line program mode
D) On-line program mode

E) B) and D)
F) A) and C)

Correct Answer

verifed

verified

The authoritative source on grounding requirements for a PLC installation is the:


A) plant electrician.
B) plant engineer.
C) equipment manufacturer.
D) National Electrical Code.

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Where line voltage variations to the PLC are excessive,a constant voltage transformer can be used to maintain a steady voltage.

A) True
B) False

Correct Answer

verifed

verified

Electromagnetic interference (EMI)may enter a PLC system through radiation.

A) True
B) False

Correct Answer

verifed

verified

Generally,output modules designed to drive inductive loads include suppression networks as part of the module circuit.

A) True
B) False

Correct Answer

verifed

verified

Malfunctions due to electrical noise interference usually cause:


A) temporary occurrences of operating errors.
B) permanent occurrences of operating errors.
C) temporary loss of memory.
D) permanent loss of memory.

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

A diode can be connected in reverse-bias across a DC solenoid to suppress voltage spikes.

A) True
B) False

Correct Answer

verifed

verified

With reference to the troubleshooting guide,which condition indicates no fault? With reference to the troubleshooting guide,which condition indicates no fault?   A) Condition (a)  B) Condition (b)  C) Condition (c)  D) Condition (d)


A) Condition (a)
B) Condition (b)
C) Condition (c)
D) Condition (d)

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

The suppression circuit shown: The suppression circuit shown:   A) can be used to suppress DC loads. B) can be used to suppress AC loads. C) uses a metal oxide surge suppressor. D) all of these.


A) can be used to suppress DC loads.
B) can be used to suppress AC loads.
C) uses a metal oxide surge suppressor.
D) all of these.

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

The force instructions:


A) will force data table bits on only.
B) will force data table bits off only.
C) if used indiscriminately,could cause haphazard machine operation.
D) can be used only to force inputs.

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

To make sure that equipment does not operate while PLC maintenance is conducted lockout and tagout devices must be in use.

A) True
B) False

Correct Answer

verifed

verified

PLC output modules may incorporate fuse or electronic protection for output circuitry.

A) True
B) False

Correct Answer

verifed

verified

Most PLC installations require additional cooling provisions,not included in the original installation.

A) True
B) False

Correct Answer

verifed

verified

With Allen-Bradley controllers ____ software is required to develop and edit programs.


A) RSLinx
B) RSLogix
C) Microsoft word
D) LogixPro

E) C) and D)
F) B) and D)

Correct Answer

verifed

verified

When routing power and I/O signal wiring to and within a PLC enclosure you should:


A) use the shortest possible wire runs for I/O signals.
B) never run signal and power wiring in the same conduit.
C) run low level signal conductors as shielded twisted pair.
D) all of these.

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified